3. Meaning and Usage of GOP Structure Parameters

3.1. Instruction and Usage of Single-Reference P-Frame GOP Structure Properties

The parameters of single-reference P-frame encoding GOP structure are shown in the following table.

Parameter

Description

Instructions

s32IPQpDelta

I-P delta QP

Adjusting I-frame quality and size, with positive values indicating that the I-frame QP is lower than the P-frame QP. By setting an appropriate delta value, the breathing effect can be reduced. Recommended value: [2,6]

3.2. Instruction and Usage of Intelligent P-frame GOP structure properties

The parameters of intelligent P-frame encoding GOP structure are shown in the following table.

Parameter

Description

Instructions

u32BgInterval

Long-term Reference Frame Interval

Required to be set as an integral multiple of GOP. Recommended to be 10-12 times the frame rate.

s32BgQpDelta

Long-term Reference Frame Delta Quantization Parameter

It needs to be set as an integer multiple of the GOP, and it is recommended to be 10-12 times the frame rate. Recommended value: [4,6]